1W415-0803 / C / 04.19.12INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.NEVER LEAVE CHILDREN OR O
10W415-0803 / C / 04.19.1216" MINIMUM40 FT MAXIMUM3 FTMINIMUMTOP VENT10" MINIMUM34"42 3/8" MINIMUM PLUS RISE*24" MAXIMUM* See
11W415-0803 / C / 04.19.123.4 SPECIAL VENT INSTALLATIONS3.4.1 PERISCOPE TERMINATIONUse the periscope kit to locate the air termination above grade. T
12W415-0803 / C / 04.19.123.5 VENT TERMINAL CLEARANCESINSTALLATIONSCANADA U.S.A.A 12” 12” Clearance above grade, veranda porch, deck or balcony.B 12”
13W415-0803 / C / 04.19.123.6 VENT APPLICATION FLOW CHART3.7 DEFINITIONS13.1TOP EXITHorizontal TerminationVertical TerminationVertical rise is equal
14W415-0803 / C / 04.19.123.8 ELBOW VENT LENGTH VALUES15.1 FEET INCHES1° 0.03 0.515° 0.45 6.030° 0.9 11.045° 1.35 16.090°* 2.7 32.0* The fi rst
15W415-0803 / C / 04.19.12(HT) > (VT) Simple venting configuration (only one 90° elbow)See graph to determine the required vertical rise VT for the
16W415-0803 / C / 04.19.123.10 REAR EXIT HORIZONTAL TERMINATIONFor vent configurations requiring more than two 90° elbows, the following formulas app
17W415-0803 / C / 04.19.12Simple venting configuration (only two 90° elbows)See graph to determine the required vertical rise VT for the required hori
18W415-0803 / C / 04.19.123.11 TOP OR REAR EXIT VERTICAL TERMINATIONSimple venting configurations.See graph to determine the required vertical rise V
19W415-0803 / C / 04.19.12Simple venting configurations.See graph to determine the required vertical rise VT for the required horizontal run HT.REQUIR
2W415-0803 / C / 04.19.12TABLE OF CONTENTSNOTE: Changes, other than editorial, are denoted by a vertical line in the margin.1.0 INSTALLATION OVERVIEW
20W415-0803 / C / 04.19.12Example:V1 = 1.5 FTV2 = 5 FTVT = V1 + V2 = 1.5 + 1 + 5 = 6.5 FTH1 = 1 FTH2 = 1 FTH3 = 10.75 FTHR = H1 + H2 + H3 = 1
21W415-0803 / C / 04.19.124.2 DOOR OPERATIONTo access the lower door latch, open the Valve Access Door as illustrated. Release the top and bottom door
22W415-0803 / C / 04.19.125.0 INSTALLATION5.1 WALL AND CEILING PROTECTIONFor clearances to combustible materials from the vent pipe, see “FRAMING” se
23W415-0803 / C / 04.19.12This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal loc
24W415-0803 / C / 04.19.125.4 USING FLEXIBLE VENT COMPONENTS5.4.1 HORIZONTAL AIR TERMINAL INSTALLATIONFor safe and proper operation of the appliance,
25W415-0803 / C / 04.19.125.4.2 VERTICAL AIR TERMINAL INSTALLATIONA. Fasten the roof support to the roof using the screws provided. The roof support
26W415-0803 / C / 04.19.12The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel Ltd. supp
27W415-0803 / C / 04.19.127.6This appliance is designed to be attached to a 3” co-linear aluminum fl ex vent system running the full length of a masonr
28W415-0803 / C / 04.19.125.6.1 VERTICAL AIR TERMINAL INSTALLATIONNOTE: Before attaching elbows to the collars on the back of the appliance, 1 1/2” wi
29W415-0803 / C / 04.19.125.7 MOBILE HOME INSTALLATIONThis appliance is certifi ed to be installed as an OEM (Original Equipment Manufacturer) install
3W415-0803 / C / 04.19.121.0 INSTALLATION OVERVIEWSee the section “MINIMUM MANTEL AND ENCLOSURE CLEARANCES”Side WallSee the section “INSTALLATION -FRA
30W415-0803 / C / 04.19.125.9 OPTIONAL WALL SWITCH EXCLUDING BCDV36CFGFor ease of accessibility, an optional remote wall switch or millivolt thermost
31W415-0803 / C / 04.19.126.0 FRAMINGIt is best to frame your appliance after it is positioned and the vent system is installed. Frame to local buildi
32W415-0803 / C / 04.19.12* HORIZONTAL VENT SECTIONS - A minimum clearance of 1" at the bottom and sides and 2" at the top of the vent pipe
33W415-0803 / C / 04.19.126.2 MINIMUM FRAMING DIMENSIONS17 1/4”1 1/2”MAX38 3/4”40 1/2”14” MIN1 1/2” MAX49” (TOP EXIT)38 3/4” (REAR EXIT)STEEL HEADER
34W415-0803 / C / 04.19.126.2.1 STEEL HEADER INSTALLATION FOR CLEAN FACE SURROUNDConvex Clean Face Surround Kit Illustrated1240 1/4”1 1/2”MAX314”MININ
35W415-0803 / C / 04.19.12The appliance requires a minimum enclosure height of 38 1/2“ (REAR VENT) 49" (TOP VENT). For tempera-ture requirements,
36W415-0803 / C / 04.19.12COMBUSTIBLEMATERIALSTEEL HEADERREQUIRED IF USING OPTIONAL CLEAN FACE SURROUNDSHELF*6 1/2” MINNON-COMBUSTIBLE MATERIAL2”2” 1”
37W415-0803 / C / 04.19.126.3.4 CLEAN FACE SURROUND MINIMUM ENCLOSURE CLEARANCES2”COMBUSTIBLE 40 1/2” *6 1/2” NON-COMBUSTIBLE 34” 2” 1” 0” IF NON-COMB
38W415-0803 / C / 04.19.12WAVES36WN (BROWN)S36WP (PEWTER)CONCAVES36CCN (BROWN)S36CCP (PEWTER)CONVEXS36CVN (BROWN)S36CVP (PEWTER)6.4 CLEAN FACE SURROU
39W415-0803 / C / 04.19.12When installing to a hearth the appliance riser must create a minimum clearance of 3 3/8" PLUS the height of the hearth
4W415-0803 / C / 04.19.122.0 INTRODUCTION3.1C!WARNING• THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED.• ANY CHANGES TO
40W415-0803 / C / 04.19.126.6 ALCOVE FRAMINGAPPLIANCERECESS OR ALCOVE AREA NOTE: Recesses or alcoves above the appliance can be made as deep as desire
41W415-0803 / C / 04.19.12To access the door latches, remove the valve control door and upper trim. To open the door, release the top and bottom door
42W415-0803 / C / 04.19.12A. From the rear side of the clean face front, insert the weld studs on the top window plate assembly upward through the ho
43W415-0803 / C / 04.19.128.0 BCDV36CF FINISHING8.1 LOG PLACEMENT!WARNINGFAILURE TO POSITION THE LOGS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO
44W415-0803 / C / 04.19.128.2 GLOWING EMBERS8.3 CHARCOAL EMBERS8.4 LOGO PLACEMENT8.5 OPTIONAL ROCK KIT32.1Randomly place the charcoal embers along th
45W415-0803 / C / 04.19.12Secure the glass ember tray to the burner using 6 screws (W570-0001).Spread the clear glass embers (W300-0102) onto the glas
46W415-0803 / C / 04.19.129.2 TOP PRP PANEL INSTALLATION GD36MTOP PORCELAIN PANELBACK PORCELAIN PANELSIDE PORCELAIN PANELSIDEPORCELAIN PANELTOP DEFLE
47W415-0803 / C / 04.19.1210.0 OPTIONAL BLOWER INSTALLATION10.1 ACCESSING THE BLOWERA. Remove the valve access door and top door trim. B. Open the
48W415-0803 / C / 04.19.1211.0 WIRING DIAGRAM!WARNINGDO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SERVICE TECHNICIAN I
49W415-0803 / C / 04.19.1211.2 BCDV36CFG BURNER SWITCH69.3A wall switch or remote control must be installed in a convenient location to operate the m
5W415-0803 / C / 04.19.122.1 DIMENSIONS34”33”24 ¼”8”3”40”15”17”27”ELECTRICAL INLETLEFT SIDEGASINLET4" DIA.7" DIA.38 ½”38 ½” ǩ”4 ǩ”3 ǫ”5”THI
50W415-0803 / C / 04.19.1211.3 RECEPTACLE WIRING DIAGRAM
51W415-0803 / C / 04.19.1212.0 OPERATIONEnsure that a continuous gas flow is at the burner before installing the door. When lit for the first time, th
52W415-0803 / C / 04.19.1212.2 BCDV36CFGEnsure that a continuous gas flow is at the burner before installing the door. When lit for the first time, th
53W415-0803 / C / 04.19.1213.0 ADJUSTMENTS13.1 PILOT BURNER ADJUSTMENTAdjust the pilot screw to provide properly sized fl ame. Turn in a clockwise dir
54W415-0803 / C / 04.19.1213.2.2 BCDV36CFG VENTURI ADJUSTMENTThis appliance has an air shutter that has been factory set open according to the chart
55W415-0803 / C / 04.19.12It’s important to periodically perform a visual check of the pilot and burner fl ames. Com-pare them to the illustrations pro
56W415-0803 / C / 04.19.12This appliance comes equipped with our “Night Light™”. If in the event the lamp or lens needs to be replaced, follow these i
57W415-0803 / C / 04.19.1214.3 DOOR GLASS REPLACEMENTA. Place the door frame face down careful not to scratch the paint.B. Center the gasketed glas
58W415-0803 / C / 04.19.1215.0 REPLACEMENTSContact your dealer or the factory for questions concerning prices and policies on replacement parts. Norma
59W415-0803 / C / 04.19.12FLEXIBLE VENT KITSREF NO. BCDV36CF BCDV36CFG DESCRIPTIONGD220 (5 FT) 35* W010-0397 W010-0397 4" FLEXIBLE VENT PIPE - (5
6W415-0803 / C / 04.19.124.1A The installation must conform with local codes or, in absence of local codes, the National Gas and Propane Installation
60W415-0803 / C / 04.19.12ACCESSORIESREF NO. BCDV36CF BCDV36CFG DESCRIPTION50* W175-0001 W175-0001 4" COUPLER51* W175-0013 W175-0013 7" COUP
61W415-0803 / C / 04.19.1240414647484953575877787973
62W415-0803 / C / 04.19.1216.0 TROUBLESHOOTING16.1 BCDV36CFSYMPTOM PROBLEM TEST SOLUTIONMain burner goes out; pilot stays on.Pilot fl ame is not large
63W415-0803 / C / 04.19.12SYMPTOM PROBLEM TEST SOLUTIONPilot will not light. No spark at pilot burner. - Check if pilot can be lit by a match. - Chec
64W415-0803 / C / 04.19.1216.2 BCDV36CFGSYMPTOM PROBLEM TEST SOLUTIONPilot will not light.Makes noise with no spark at pilot burner.Wiring. - Verify
65W415-0803 / C / 04.19.12SYMPTOM PROBLEM TEST SOLUTIONCarbon is being deposited on glass, logs, rocks, media or combustion chamber surfaces.Air shutt
66W415-0803 / C / 04.19.1217.0 WARRANTYCONTINENTAL® warrants its products against manufacturing defects to the original purchaser only. Registering yo
67W415-0803 / C / 04.19.1218.0 SERVICE HISTORY43.1
68W415-0803 / C / 04.19.12
7W415-0803 / C / 04.19.123.1 RATING PLATE INFORMATIONINSTALLER: It is your responsibility to check off the appropriate box on the rating plate accord
8W415-0803 / C / 04.19.123.2 VENTING LENGTHS AND COMPONENTSUse only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or M
9W415-0803 / C / 04.19.123.3 TYPICAL VENT INSTALLATIONSREQUIRED RISE ON HORIZONTAL VENTINGREAR VENT RIGID 0" / FTFLEXIBLE 0" / FTTOP VENT R